Five Eight Twelve
Home
LocationsAboutContactGet a Quote
A compact city and a farming township share the name, and they do not share a rulebook. We settle which one your address answers to, and what the ground and the services out there allow, before a system is chosen.

City of Langley & Township of Langley

Exterior Screens, Patio Covers & Awnings for Langley City and Township

A compact city and a farming township share the name, and they do not share a rulebook. We settle which one your address answers to, and what the ground and the services out there allow, before a system is chosen.

Two governments, opposite starting pointsOne publishes a small structure exemption and one publishes none. We work out which applies to your address before we quote.
Residential & commercialSubdivision decks and acreage yards through to village cafe frontages and agricultural premises.
Sized to a 2.4 kPa ground snow loadThe building code figure published for Langley sits a third above Vancouver City Hall, and member sizing follows the address rather than a catalogue.
Design & specificationFootprint, post positions and fixing detail resolved against the property, its services and its setbacks before an order goes in.
Motorization & automationSomfy and Gaposa control, with sensor thresholds set for how exposed the site actually is rather than for a default.
Warranty registrationManufacturer terms recorded and registered as part of closing the job out.

Six Langley Numbers That Change What Gets Built

Four of these come out of Appendix C of the BC Building Code, which publishes one Langley row and does not split the City from the Township. The other two come out of what the two municipalities ask for on the ground. Where a sentence moves from a published figure to what we do about it, it says so, because the code publishes loads and temperatures and nothing else.

Langley is one name over two building departments and two completely different kinds of property. The City starts from a published exemption on a small urban lot. The Township starts from a bylaw where every structure needs a permit, on a lot big enough to put the structure almost anywhere. So the first decision on a Langley project is not which roof you want. It is which Langley you are in, and what the ground out there will give you.

01

A 2.4 kPa snow load, which is not the coast's

Table C-2 lists Langley at a 1-in-50 ground snow load of 2.4 kPa with an associated rain load of 0.2 kPa. Vancouver City Hall in the same table is 1.8 kPa and Richmond is 1.5 kPa, so Langley carries roughly a third more than a downtown installation and 60 percent more than Richmond. A solid roof, a glazed roof and a louvered roof with the blades shut all carry the whole of it. What we take from that figure, rather than what the code says about it, is that post count, member depth and footing size get calculated for the address instead of copied off a size chart.

02

An inland swing the water facing municipalities do not get

The same table gives Langley a January 1 percent design temperature of -10 C and a July 2.5 percent design of 29 C dry bulb. North Vancouver is -9 C and 26 C, Richmond is -9 C and 27 C. Langley is both colder in winter and hotter in summer than either, which pulls one design in two directions inside a single year. Our reading of it: on a 29 C afternoon the job is heat as much as glare, which favors stopping solar gain outside the glazing rather than trapping warm air under a fixed roof, and on a clear winter evening it is radiant output that keeps a space usable. The wider annual range is also why we detail long aluminum runs to move rather than bolting them solid at both ends.

03

Rain volume is one problem, rain intensity is another

Appendix C gives Langley 1450 mm of annual rain, 1500 mm of total annual precipitation, a 15 minute rain of 10 mm and a 1-in-50 one day rain of 112 mm. The annual figure tells you how often water moves through a system. The 15 minute figure is the one that sizes it, because a roof fails at the burst and not at the average. Gutter section, outlet count and downpipe routing are ours to get right. Where the water is then allowed to go is a question the City of Langley starts answering for you once new roof area passes 25 square metres, which is set out further down this page.

04

The wind pressure is ordinary, the exposure is not always

Table C-2 puts Langley's 1-in-50 hourly wind pressure at 0.44 kPa, the same figure it gives Cloverdale, Surrey and New Westminster, so the reference pressure is not what sets this market apart. Terrain is. Approximately 75 percent of the Township's land area is in the Agricultural Land Reserve, so an acreage can face open field with nothing upwind of it, while a Willoughby or Walnut Grove subdivision lot has three rows of houses doing that work already. On the exposed version we would rather fit a wind sensor set to retract early, size footings for uplift as well as downward load, and specify side retained screens over open hems. Those are consequences of exposure, not figures anyone publishes.

05

A septic field and a well decide where the posts land

The Township's residential construction guide asks for septic system and well locations on the site plan, and on a property with septic it wants a Registered Onsite Wastewater Practitioner to complete a Fraser Health record of filing, or a building permit referral form where filing is still in progress, before the permit is issued. On an acreage the disposal field and the well very often occupy exactly the flat, open, sunny ground behind the house that a freestanding structure wants. Post positions then get laid out around them, and that sets beam spans and beam depth. It is a survey question to settle before a layout is drawn, and your own site needs confirming with the Township.

06

In the City, drainage takes up part of the yard

The City of Langley requires a professional geotechnical engineer to report on the suitability of the soil and the depth of the groundwater table, and requires amended soils unless native infiltration exceeds 50 mm per hour. On unserviced lots in South Langley an infiltration gallery must sit at least 5 m from the nearest building foundation and at least 1 m from a property line, and impervious surfaces are not permitted. On a small urban lot the gallery and its keep out distances can take up the same rear yard the covered patio was meant to occupy. Deciding where a new roof discharges is therefore an early design decision here, not an installation day detail.

The Three Systems We Specify Most in Langley

Each block below is about how the system behaves on a property here. The ranges, the brands and the specification stay on the linked pages, which is deliberate rather than an omission.

01Sun, wind and privacy

Exterior Shade Screens

A screen does the two jobs a roof cannot do at all: it stops low sun and driven rain arriving from the side, and it closes a flank without walling a space in. On a Langley lot the detail that decides whether it works is retention. Held in a track or by a side retention system, the fabric keeps its shape when a gust crosses open ground. Left on an open hem it bows and slaps. On a hot afternoon a screen outside the glass also stops the heat before it reaches the room, which is a different result from a blind sitting behind it.

  • Side retained or track guided, so the fabric holds its line in a gust
  • Low sun and driven rain that overhead cover never reaches
  • Fitted into a new structure, or run alone across an existing opening
  • Solar gain stopped outside the glazing rather than after it arrives
  • Sun and wind sensor automation, wall or app control
How the exterior screen systems compare
Guided exterior shade screen lowered across a residential patio opening
02Shade when you want it

Retractable Awnings

The case for one in this climate is seasonal. It covers the deck through the hot afternoons Langley genuinely gets, then folds away instead of standing out through a winter that carries a 2.4 kPa design snow load. Where the unit sits once it is closed is the real specification question. Under a deep soffit an open lateral arm system is fine. Out on an exposed elevation a closed cassette that seals the fabric and the motor away earns its cost back quickly.

  • Out for the afternoon, stored before the weather that would load it
  • Closed cassette where the unit is exposed, open arm where it is sheltered
  • Wall, soffit or beam mounting depending on what is behind the cladding
  • Wind sensor thresholds set to how open the site actually is
  • House decks, acreage terraces and commercial frontages
Which awning system suits your mounting
Freestanding retractable terrace awning extended over an outdoor seating area
03Permanent cover

Patio Covers

A fixed roof is the answer where the space has to work in February as well as July, and it is also the version of this project that meets the most rules. In the City, covering a sundeck appears by name on the list of work needing a building permit, and new roof area over 25 square metres pulls a rainwater management plan and a covenant on title along with it. In the Township there is no published small structure exemption to fall under in the first place. None of that argues against building one. It argues for settling the footprint, the drainage and the approval route before anything is ordered.

  • Cover that works through the wet months rather than on demand
  • Glass, polycarbonate and aluminum roof options
  • Drainage worked out against a 10 mm fifteen minute rain, then routed deliberately
  • Attached to the house, or freestanding out in the yard where the zoning allows it
  • Screens, heating and lighting mounted into the same frame
Patio cover and sunroom options
Glazed residential patio cover with vertical sliding glass panels

Three More That Turn Up on Langley Jobs

Each one is summarized here for how it behaves on a Langley property, then linked. The full system detail belongs on the product pages.

Freestanding radiant patio heater beside outdoor seating on a deck

Outdoor Heating

A January 1 percent design temperature of -10 C, colder than the figure the same code table gives North Vancouver or Richmond, is what ends a shoulder season evening out here. Radiant infrared warms people and surfaces instead of air, so it still works in a space open on one or more sides. On an acreage a freestanding unit can follow the seating rather than the building, and on a fixed cover the heat mounts into the structure and off the floor.

Read about Bromic radiant heating >
Rolling shutters installed over residential windows

Roll Shutters & Rolling Security

One product family covering two jobs that both come up here. On a house it closes a west facing window down completely for heat and light, and secures a property that sits empty in stretches. On a farm building, a shop or a light industrial unit it protects an opening out of hours. The product page holds the detail.

Roll shutter and rolling security systems >
Aluminum louvered roof with the blades open above a patio

Pergolas & Louvered Roofs

An adjustable blade roof suits a climate that runs hot in July and shuts down in January, because the same structure opens to the sky and closes to a sealed roof. It is deliberately a supporting section on this page, because the system detail belongs on the product page. The local point worth making is that a closed louvered roof carries the full snow load, so the frame is engineered to the site like any other solid roof.

Louvered roof and pergola systems >

Two Very Different Kinds of Langley Property

A house and a business are not the same brief. Take the side that describes yours.

Motorized exterior screens enclosing a residential covered patio

The residential question here splits on lot size before it splits on taste. A quarter acre in the Township and a compact lot in the City are answered by different structures.

Township lots with room to build away from the house

Where a freestanding structure is a real option, it stops competing with the roofline and the window heads, and the shade lands where the seating already is. The zoning numbers that make this possible are in the spotlight below.

Acreage and semi rural sites facing open ground

Nothing upwind changes the hardware rather than the layout: retained screens, a conservative sensor threshold and footings resisting uplift as well as weight.

Newer subdivision decks with nothing over them

A large unshaded deck on a recent build usually wants one overhead system and one closed flank rather than a bigger roof.

Compact lots and townhouse patios in the City

Small urban ground where setbacks, lot coverage and rainwater all land on the same few square metres. What the structure may project into a required yard becomes a live question early.

Properties on a well and a septic field

The services decide the layout. Post positions follow the disposal field, and the field is located on a site plan before a beam span exists.

The Township allowance the City does not have

Building It Away From the House

The largest practical difference between the two Langleys is how much freestanding structure the zoning allows and how tall it may be. On a suburban or rural Township lot the published numbers are generous enough that the footprint is rarely what constrains the design. In the City's R1 zone they are not. Every figure here is quoted from the bylaw that governs it, and each document is linked in the approvals section below.

Height is where the two diverge most

Section 301.6 2) of Township Zoning Bylaw 2500 allows non farm accessory buildings and structures in the SR-1 suburban zone up to 7.5 m. The City's R1 schedule sets maximum height for accessory buildings and structures at 4.6 m. That gap decides whether a tall freestanding roof over a pool deck or an outdoor kitchen is even a conversation. Zones differ within each municipality, so check the one your property actually carries.

Ground floor area, side by side

SR-1 caps non farm accessory buildings and structures at a total of 135 square metres of ground floor building area and holds lot coverage for all buildings and structures at 33 percent. The rural RU-1 zone allows a total of 200 square metres on the same 33 percent, and 66 percent where commercial greenhouses are involved. The City's R1 zone caps the total floor area of accessory buildings on a lot at 60 square metres with maximum lot coverage of 36 percent.

Eighty square metres is a step in the setbacks

Township section 301.5 2) sets SR-1 accessory setbacks at 9.75 m from a front lot line, 1.5 m from a rear lot line, 1.5 m from a side lot line and 4.5 m where a side lot line abuts a flanking street. Both the rear and the side figures rise to 3 m once the structure reaches 80 square metres, and below 6 square metres they drop to 0.6 m. A footprint of 8 m by 10 m lands exactly on that step, which is worth knowing before the size is fixed.

Lot coverage is counted differently on each side of the line

The City's Zoning Bylaw 3300 defines lot coverage as the percentage of a lot covered by buildings and enclosed structures. The Township's definition in Section 102 counts all buildings and structures or projections thereof, with no enclosure test, although some zone schedules carve items out and others do not. Whether a specific open sided cover counts is a determination for staff either way. The point is that the two definitions do not read the same, so read the one that applies to you rather than the one you read last.

The Township asks for a signed declaration with it

An accessory building permit application in the Township comes with a Declaration of Intended Use, signed by the owner and given the same force as a statement made under oath. It confirms compliance with Zoning Bylaw 2500, that the structure is for personal use rather than commercial or industrial purposes, and that it will not be converted into habitable space. It is a small piece of paperwork and an easy one to be caught out by at application.

Freestanding aluminum shade structure set away from a house in an open yard

Commercial outdoor dining

Village Frontages, and Anything That Reaches the Street

The first thing an operator needs is not a product fact. It is that two of the most attractive commercial settings in Langley are heritage conservation areas, and that anything overhanging municipal property is a separate approval carrying its own insurance condition. The documents named below are linked in the approvals section.

Fort Langley and Murrayville are heritage conservation areas

The Township states that there are currently two heritage conservation areas in the Township, in Fort Langley and Murrayville, and that heritage conservation areas typically require a Heritage Alteration Permit to subdivide, alter or demolish existing buildings, structures, features or land within the area, or to construct new ones. Its development permit brochure adds that in a heritage conservation area a Heritage Alteration Permit is required in lieu of a development permit, and that the process for issuing one is the same. Section 104.5 2) of Zoning Bylaw 2500 separately caps building height in the mapped Fort Langley area at 9 m and two storeys.

The planning approval comes before the building permit

The Township puts the sequence plainly: in a development permit area, a development permit must first be issued before a building permit may be obtained. Its brochure extends that to most additions or alterations to existing buildings and structures, not only to new ones, which is the part that catches a canopy or a cover going onto a building that is already trading. The full wording and the four area types are in the approvals section below.

Overhanging municipal property is its own permit

The Township's engineering forms page describes its annual Highway Use Permit as the way to apply to have private infrastructure overhang municipal property, naming awning signs, sandwich boards, patio furniture and blade signage. The form itself requires evidence of commercial general liability insurance of at least $3,000,000, with a cross liability clause and the Township named as an additional insured. That is a separate approval from the building permit, with a condition that takes time to arrange.

In the City, zoning fixes the canopy geometry

For all commercial zones the City's Zoning Bylaw publishes a clearance to the curb line and a minimum height to the underside of a canopy. Those two numbers govern the shape of a fixed awning over a City frontage before anything structural does, and both are quoted in the approvals section below. A building permit and any use of City property are separate questions again.

What we could not find, and are not going to invent

We looked for a current City of Langley sidewalk patio or outdoor dining program document and could not reach one. An older guide is indexed by search engines but the file now returns an error, and the City's live building permits page blocks automated reading. So this page says nothing about a City sidewalk patio program, any encroachment agreement or any parking relief. If that is your project, ask the City directly rather than working from anything published elsewhere.

Fixed frame fabric awning over a cafe frontage

Local planning

City of Langley or Township of Langley? Start There

These are two separate local governments, and on the question that matters most their published starting points run in opposite directions. The City publishes an area below which a detached building needs no permit. The Township's building bylaw states that a permit is required for all Construction and publishes no equivalent threshold. Everything below is quoted from each municipality's own current documents, read on 19 September 2026. Treat it as where a conversation with them begins, not as an answer about your own address.

City of Langley

The small urban half. It names covering a sundeck as permit work, it publishes a clear line for detached buildings, and it counts only enclosed structures toward lot coverage. It also carries a trigger most Lower Mainland municipalities do not publish: added roof area above 25 square metres brings a geotechnical rainwater plan and a covenant on title into an ordinary residential permit. Council adopted Zoning Bylaw 2025 No. 3300 on 9 March 2026, so older guides quoting the previous zone names are out of date on zoning even where they remain correct on process.

01

Covering a deck is named as permit work

The City's single family addition and alteration guide puts construct, cover or enclose a porch or sundeck on the list of work a building permit is required for, alongside adding to a building and converting a carport. Its residential application form then asks for Sundeck Area and Sundeck with Roof Area as two separate figures. Few municipalities are that direct about roofing over an existing outdoor space. Confirm your own structure with the City of Langley Building Division before anything is ordered.

02

Where the line falls for a detached building

The City's accessory building guide states that detached buildings under 10 square metres, which it gives as 107.64 square feet, do not require a building permit, however must comply with the setback requirements set out in the City of Langley Zoning Bylaw for accessory buildings. The same guide restates that no erection, alteration, enlargement, repair, removal or demolition of any building or structure may be commenced without a permit being obtained first. Staying under the line removes the permit, not the siting rules. The guide is dated 12 April 2022, so treat the zoning figures inside it as superseded by Bylaw 3300 and confirm the current position with the City.

03

Added roof area above 25 square metres brings in an engineer and a covenant

The City's Integrated Rainwater Management guides set an exemption ceiling tied to roof area on single family lots. For an addition the test is an additional roof area of 25 square metres or less. For an accessory building it is total roof area under 25 square metres. Above that, the City publishes a requirement for an Integrated Rainwater Management plan designed by a professional geotechnical engineer with a soils report, and a restrictive covenant registered against the property at the Land Title Office. On unserviced lots in South Langley, roughly south of Grade Crescent and 50 Ave between 196 Street and 210 Street, the same threshold brings in an infiltration gallery set at least 5 m from the nearest building foundation and at least 1 m from a property line. A solid roofed patio cover passes 25 square metres easily, so this is worth raising with the City early.

04

Lot coverage counts enclosed structures only

The definition in Bylaw 3300 turns on one word: lot coverage means the percentage of the area of a lot that is covered by buildings and enclosed structures. That wording is not the same as the Township's, which counts all buildings and structures and their projections. Anyone comparing a City project with a Township project should read both definitions rather than assume they work alike, and which side of that line a particular open sided cover falls on is a determination for City staff.

05

What the R1 zone allows an accessory structure to be

In the R1 Suburban Residential zone the bylaw states that the maximum total floor area of accessory buildings on a lot is 60 square metres. The same schedule sets maximum height for accessory buildings and structures at 4.6 m, maximum lot coverage at 36 percent, and minimum accessory setbacks of 6.0 m front, 1.5 m rear, 1.5 m interior side and 3.0 m exterior side. It also requires an accessory building in R1 to sit at least as far from the front lot line as the principal building and at least 1.0 m from it. Check which zone your property is in before applying any of these.

06

Rooftop patios are out in R1

The Other Regulations block of the R1 schedule states that roof top patios are prohibited. That closes off the roof deck with a shade structure over it which gets proposed on constrained urban lots elsewhere. It sits in the R1 schedule specifically and is the only occurrence in the bylaw, so it is not a statement about every zone in the City.

07

What may project into a required yard, and what may not

The Projections Into Yards section names sun shades among the features allowed to project up to 1.0 m into a required front, side or rear yard in all single family and multiple residential zones, alongside eaves and gutters, cornices, sills, bay windows, chimneys and steps. Separately, the All Zones line permits steps, arbors and trellises, ornaments, flag poles and similar landscaping features, and uncovered patios or terraces. Covered patios are not on that All Zones list. If a structure has to sit inside a setback, this wording is where the conversation with the City starts.

08

Commercial canopies get their own two numbers

For all commercial zones the bylaw allows marquees and canopies to project provided they come no closer than 1.0 m to the vertical projection of the curb line, and requires the minimum height of the underside of a canopy to be 2.5 m. That pair governs a fixed awning or canopy over a City frontage or a sidewalk facing patio. It is a zoning rule. A building permit, and any use of City property, are separate questions to put to the City.

09

Strata property needs the corporation's written consent

The City's Agent Authorization form carries a second page for strata title properties on which a member of the strata council confirms that consent of a strata corporation is required for work that will involve or affect common property and limited common property, including work altering limited common property adjacent to a named unit. A townhouse patio or terrace is very often limited common property, so the City's paperwork asks for the strata council before it asks for much else. Read your own strata bylaws alongside it.

What applies depends on which of the two Langleys you are in, on the property, and on the structure itself. Five Eight Twelve supplies the project and system information an application needs. Confirming and obtaining the permits and approvals stays with the property or business owner.

Before you ask for a number

Where the Money Actually Goes on a Langley Project

No prices here, because a figure with no specification attached tells you nothing you can act on. These are the variables that set one, with the approval items kept as their own group because in this market they are the ones people have not budgeted for. Select what describes your project to see what a quote will turn on.

Size and system

The site

Services and integration

Approvals, which bite harder here

What your quote will hinge on

Select the factors on the left that describe your project.

  • Size and system
  • The site
  • Services and integration
  • Approvals, which bite harder here

This is the checklist a site visit works through before a number exists. In this market the approvals group is the one that most often changes the answer, which is why it is listed rather than hidden inside a contingency.

Langley Projects

Nothing published from this market yet

We have not published a Langley installation with the client's permission, the municipality and the system all stated, and that is the only way a job belongs in this space. Filling it with work from somewhere else and letting the address do the implying is not something we are willing to do. The three images below are product and system photography rather than local projects.

Exterior zip guided shade screen lowered over patio doors
Aluminum framed patio cover above a residential deck
Box cassette retractable awning mounted above a terrace

Product and system photography. Not Kelowna or West Kelowna projects.

How a Langley Project Runs

The same sequence we follow in every market, with the second and fifth steps carrying more weight here than they do elsewhere.

  1. 01

    Consultation

    You describe the space, how you want to use it, and the point in the day or the year at which it stops being any good to you. From that we fix the scope and decide which system families are worth pricing.

  2. 02

    Site and project review

    Orientation, exposure, what the mounting surface is, where the services run, how open the ground is, and which of the two municipalities the property answers to.

  3. 03

    System and design options

    The options that are actually realistic for the site, with the trade offs said out loud, including what each one will not fix.

  4. 04

    Proposal and quote

    A written specification with the system named, the sizes fixed, the finish chosen, the integration listed and the installation scope set out.

  5. 05

    Approvals confirmed

    You confirm and obtain what your municipality requires, whether that is a building permit, a rainwater plan, a development or heritage permit, or a highway use permit. We hand over the project and system information that supports it.

  6. 06

    Installation

    Supply and fit to the agreed specification, scheduled around site access and, on a commercial property, around trading hours.

  7. 07

    Handover

    We run through operation and the controls, leave you the care guidance, and register the warranty.

Step two does most of the work on a Langley job. Knowing whether you are in the City or the Township, and knowing where the well and the field are, changes the design and the approval route before any system is chosen.

Straight answers

Langley Questions

Do I need a building permit for a patio cover in Langley?

That depends on which Langley. In the City, the single family addition and alteration guide lists construct, cover or enclose a porch or sundeck among the work a building permit is required for, and the accessory building guide states that detached buildings under 10 square metres do not require a permit but must still comply with the zoning setbacks for accessory buildings. In the Township the starting point is different and there is no equivalent exemption. Confirm your own structure with your own municipality before ordering anything.

Source: City of Langley, Single Family Addition or Alteration application package

Does the Township of Langley have a size below which no permit is needed?

We could not find one. Section 5.1 of the Langley Building Bylaw states that a permit is required for all Construction, and the bylaw's definition of Structure reaches anything fixed to, supported by or sunk into land or attached to a building. Neither the bylaw nor the Township's residential construction guide publishes an area or height below which an accessory roofed structure is exempt. Treat the City's 10 square metre line as a City rule and ask the Permits, Licences and Inspections Division about your own structure.

Source: Township of Langley, Langley Building Bylaw No. 4642

What snow load does a structure here have to be built for?

Appendix C of the BC Building Code gives Langley a 1-in-50 ground snow load of 2.4 kPa with an associated rain load of 0.2 kPa, and a 1-in-50 hourly wind pressure of 0.44 kPa. Vancouver City Hall in the same table is 1.8 kPa of snow and Richmond is 1.5, so a structure that suits a lot across the river is not automatically right on this one. The code publishes one Langley row and does not separate the City from the Township. Neither municipality publishes a figure of its own.

Source: BC Building Code 2024, Division B, Appendix C, Table C-2

Why would a bigger roof bring in a geotechnical engineer?

In the City of Langley the rainwater requirement is tied to roof area. The published exemption is an additional roof area of 25 square metres or less for an addition, or total roof area under 25 square metres for an accessory building. Above that the City requires an Integrated Rainwater Management plan designed by a professional geotechnical engineer with a soils report, plus a restrictive covenant registered against the property at the Land Title Office. A solid roofed cover of any useful size passes that line, so it is worth raising at the first conversation rather than at application.

Source: City of Langley, accessory building and Integrated Rainwater Management package

Can I put a freestanding structure out in the yard on an acreage?

The zoning is often the easy part out there. In the Township's SR-1 suburban zone, non farm accessory buildings and structures may total 135 square metres of ground floor area and reach 7.5 m in height, with lot coverage for all buildings and structures held at 33 percent. In the rural RU-1 zone the accessory total rises to 200 square metres. What the permit still requires is separate, and so is whether the ground you want is already taken by a disposal field, a well or a watercourse setback. Check which zone your property carries before applying any of those numbers.

Source: Township of Langley, Zoning Bylaw 2500, Section 300 Suburban Residential Zones

My property is in the Agricultural Land Reserve. Does that change things?

It adds a second level of government to the question. The Township publishes that approximately 75 percent of its land is in the Agricultural Land Reserve and that protecting this land from non-farm uses and subdivision is a key goal of both the Agricultural Land Commission and the Township. Applications under the Agricultural Land Commission Act go through the Commission's own portal, are reviewed by Township staff and Council, and are decided by the Commission. Ask both before design work starts, because the answer shapes what is worth drawing.

Source: Township of Langley, Agricultural Land Use

There is a creek along the back of my Township property.

Then check the classification before the layout. Schedule 3 of the Township's Official Community Plan establishes Streamside Protection and Enhancement Development Permit Areas along watercourses that are not in the Agricultural Land Reserve. Non disturbance setbacks follow the watercourse's classification on the Township's mapping, are measured from top of bank, and reach 30 m for a Class A natural watercourse. The brochure also states that where a project has not been through the development approval process, streamside requirements may be applied at building permit stage. Inside the ALR, senior government streamside requirements apply instead.

Source: Township of Langley, Streamside Protection and Enhancement brochure

We run a restaurant in Fort Langley. What comes first?

The heritage conversation. The Township states that there are currently two heritage conservation areas in the Township, in Fort Langley and Murrayville, and that heritage conservation areas typically require a Heritage Alteration Permit to alter existing buildings, structures, features or land or to construct new ones. Its development permit brochure adds that such a permit is required in lieu of a development permit and follows the same process, and that in a development permit area the permit comes before the building permit. If anything overhangs municipal property there is an annual Highway Use Permit on top, with a $3,000,000 liability insurance condition.

Source: Township of Langley, Recognition and Protection

Can a structure sit inside the setback if the yard is tight?

The two municipalities allow different amounts, which is a good example of why the boundary matters. The City's Projections Into Yards section names sun shades among the features that may project up to 1.0 m into a required front, side or rear yard in single family and multiple residential zones. The Township caps the equivalent reduction at 0.6 m and applies it only to the projecting feature, naming sunlight control projections and canopies. Neither is a general permission to build in a setback, and both are worth putting to staff with a drawing rather than a description.

Source: Township of Langley, Zoning Bylaw 2500, Section 100 Administration

What does a 20 foot by 20 foot patio cover come to?

We do not publish a figure, and the reason is visible in that question. Twenty by twenty is about 37 square metres, which in the City of Langley is well past the 25 square metre roof area line that brings a geotechnical rainwater plan and a covenant into the application. That single fact can move the total more than the choice between two roof materials. Span, roof type, whether it is attached or freestanding, what the posts are landing on and the approval route all sit ahead of any price, which is what a site visit is for.

What actually works for heating an outdoor space through a Langley winter?

Radiant infrared, fixed into the structure or standing in the seating area rather than trying to warm the air. A space open on one or more sides cannot hold warm air at all, so convection output leaves as fast as it is made, and the January 1 percent design temperature here is -10 C, colder than the code gives either North Vancouver or Richmond. Radiant output puts its energy straight into people and the surfaces around them. Neither Langley municipality publishes requirements of its own for outdoor heating appliances that we could find, so clearances come from the manufacturer's own instructions.

Source: Bromic outdoor heating

Are screens actually worth it on an open lot?

On an exposed site they usually change more than the roof does. Overhead cover does nothing about sun arriving sideways in the late afternoon, and it does nothing about wind crossing open ground into the one side of the space you sit on. A retained screen closes that flank in seconds, cuts the low glare, gives privacy where a neighbour looks straight in, and rolls away when conditions are fine. The specification detail that matters is retention: a screen held at its sides holds shape in a gust where an open hem screen does not.

Do you handle the permit application for me?

No. Confirming what is required and obtaining it stays with the property owner, and we would rather say that plainly than leave it vague. What we provide is the system specification, dimensions, loads and product information an application or an engineer asks for, in the form the municipality wants it. Knowing which of the two Langleys you are in is the first thing that conversation needs.

Do you have a Langley office or showroom?

No. Five Eight Twelve is a Vancouver company and every Langley project runs from there, with site visits arranged as part of the consultation. There is no local branch, no local crew listed under a Langley address and no Langley phone number, because none of those exist. What there is, is design, supply and installation across both municipalities.

Working Across Both Langleys

Five Eight Twelve designs, supplies and installs in the City of Langley and in the Township of Langley. The Township communities include Willoughby, Walnut Grove, Brookswood and Aldergrove, and the two heritage conservation areas at Fort Langley and Murrayville. Which municipality an address belongs to is not always obvious from the mailing address, and it changes almost everything on this page, so it is the first thing we establish.

Surrey, Abbotsford and the rest of the Fraser Valley are separate municipalities with their own requirements and are not covered by this page. Tell us where the property actually is and we will say directly whether we can take it on.

City of Langley, BCTownship of Langley, BC

Give us the address first. The product can wait.

Ready to plan your project?

Which of the two Langleys you are in, how open the ground is, and where the services run will shape the answer more than any preference between one roof and another. Send us the address and what the space is not doing for you, and we will come back with what suits it and what it will need approved.

Luxury Patio
Call UsSMS TextEmail Us